LK Manifold Cabinet UNI 350, UNI 450, UNI 550 and UNI 700The cabinets are manufactured from powder coat painted sheet steel, colour white RAL 9016.All cabinets are NT VVS 129 approved.LK Manifold cabinet UNI can be recessed into a wall; use LK Frame/hatch UNI INB for this type of installation. LK Manifold cabinet UNI can also be mounted onto wall; use LK Frame/hatch UNI UTV for this type of installation together with LK Base UNI. When LK Manifold Cabinet UNI 550 is installed in a ceiling, use LK Frame/hatch UNI 550 TAK. NOTE! The manifold cabinet, frame/hatch and base are separate items and must be ordered individually.The cabinet is intended for 2 pcs LK Manifolds with max number of outlets as shown in table. The brackets for the manifolds are supplied in the cabinet. The brackets are easily repositioned to connect pipes from below or above. A complete LK Drainage bend V2 is supplied for passage through a wall with a leakage indicator from the manifold cabinet. A protective bag for covering the cabinet during construction period is included. NOTE! In cases were a feed pipe is drawn inside the cabinet, the maximum number of outlets may be reduced.To maximize the number of outlets in the manifold cabinet the cold tap water pipe should be placed on the left side in the cabinet and serve the lower manifold. The hot tapwater pipe should be placed on the right side and connected to the upper manifold.Correspondingly for heating water the supply line should be placed on the left side in the cabinet and serve the lower manifold. The return line pipe should be placed on the right side and connected to the upper manifold. Feed pipes with a maximum conduit pipe dimension of 34 mm may be passed through from below, from either side or from above. Outgoing pipes with a maximum conduit pipe dimension of 34 mm may be passed through from the top or bottom of the cabinet. If LK PAL Universal pipe A with conduit 44 mm A32 PiP is connected must LK Pipe inlet 44 conduit be used, Art. no. 241 95 95.The cabinet will require additional sealing grommets depending on how many pipes are entering and exiting the cabinet. Note! Separate articles:• To pull a 25 mm conduit through an inlet hole, the LK Pipe Inlet Conduit 25 (sealing grommet) is used, Art. no. 187 44 83.• To pull conduit/pipe sizes 12-34 mm through an inlet hole, the LK Pipe Inlet UNI (sealing grommet) is used, Art. no. 187 44 84 (cropped to correct diam).To assemble and to accommodate the drain pipe, the cabinet must be installed on a min. height of 250 mm from the base of the cabinet to the finished floor. The drain pipe should be installed sloping downwards.When mounting on a wall, locate the cupboard 250 (±25) mm above the finished floor to leave room for the skirting.
NOTE: If a main riser is run inside the cabinet, the maximum number of outlets may be reduced by one or more.
LK Leakage Indication Flange
LK Pipe inlet 32 PiP
LK Manual Pipe Grip Plier
LK Frame/hatch UNI TAK
LK Fire Hatch UNI
LK Drainage elbow cutter V2
LK Outlet Plate V2
LK Pipe Inlet UNI
LK Frame/hatch UNI INB
LK Frame/hatch UNI UTV
LK Pipe Inlet 25 conduit
LK Frame/hatch UNI 350+350 INB
LK Wood screw
LK Cage nut
LK Gasket
LK Sealing Plug Black 40
LK Manifold bracket UNI-cabinet high
LK Manifold bracket UNI-cabinet low
LK Assembky kit for Frame/Lid GV/UNI UTV
LK Splash protection
LK Increased frame
LK White plug cabinet side
LK Accessory bag UNI cabinet
LK Replacement plate pipe inlet
LK Drainage elbow V2 complete
LK Manifold UNI
LK Manifold UNI 2+2
LK Manifold UNI-Valve
LK Manifold UNI PushFit AX
LK Manifold UNI PushFit AX 2+2
LK Manifold UNI PushFit AX Valve
Our website uses cookies
We use cookies to ensure that we give you the best user experience on our website. By using our website you accept our use of cookies.
Find out more about cookies