The LK Actuator Relay 24 V is intended for use when up to 12 LK Actuators 24 V need to be connected to one actuator output in the LK Connection Box or LK Receiver ICS.The LK Actuator Relay is activated from optional actuator output in the LK Receiver ICS or LK Connection Box NO, thereby enabling up to 12 actuators to be controlled from the same channel/thermostat. The LK Actuator Relay 24 V is supplemented with LK Transformer 230/24 V. Either the LK Actuator 24 V NO (normally open) or the LK Actuator 24 V NC (normally closed) can be connected to the LK Actuator Relay 24 V. All LK Actuators 24 V that are connected must be of the same type.